To choose a deep well pump, start with the pumping (dynamic) water level, sustainable well yield, required delivery flow and total dynamic head—not the depth of the well alone. Then confirm the borehole diameter, pump setting depth, water quality, electrical supply and the selected model's performance curve. The pump must deliver the required flow at the calculated head without exceeding the well's sustainable output.
A 90 m well does not automatically require a pump rated for 90 m of head. These measurements describe different things:
| Measurement | What It Means | Why It Matters |
|---|---|---|
| Total well depth | Distance from ground level to the bottom | Installation space and sediment clearance; not the required lifting head by itself |
| Static water level (SWL) | Water level when the well is not being pumped | Reference for calculating drawdown |
| Pumping / dynamic water level (PWL) | Water level at the expected pumping rate | Primary water-level input to the pumping head calculation |
| Pump setting depth | Depth at which the submerged pump is installed | Submergence, cooling, cable and installation clearance |
Drawdown = pumping water-level depth − static water-level depth. It is the change in the water level during pumping, not an additional head term to add again to pumping water-level depth.
For a simplified open-well supply system, use the expected pumping water level as the starting elevation and add the required delivery elevation, outlet pressure and friction losses. Use a consistent datum and avoid double-counting height or pressure.
Total Dynamic Head (TDH) ≈ pumping water-level depth below ground + discharge elevation above ground + required outlet pressure head + friction losses
Consider the following illustrative values, not measurements from a Stream installation:
| Total well depth | 90 m |
| Static water level below ground | 24 m |
| Pumping water level below ground | 40 m |
| Pump setting depth below ground | 58 m |
| Delivery point above ground | 8 m |
| Required outlet pressure | 15 m of water |
| Estimated pipe and fitting losses at design flow | 7 m |
| Required pump duty point | 2 m³/h at 70 m head |
The calculated head is 40 + 8 + 15 + 7 = 70 m, assuming a design flow of 2 m³/h. The pump is set at 58 m to remain submerged under the illustrative 40 m pumping water level; 58 m is not added again to TDH. Here the calculated drawdown is 16 m. In a real installation, the measured pumping water level and friction losses may change with flow and season.
The well's verified sustainable yield must also support the proposed 2 m³/h withdrawal rate. If it cannot, a higher-capacity pump will not solve the water-source limitation.
Request a borehole pumping-test record, including flow rate, stabilized pumping level (or measured level over the test), recovery data and any recommended abstraction limit. A pump with a higher maximum flow than the well can sustain may draw the level down excessively, increasing dry-running and sediment risks.
Where pumping levels fluctuate significantly, assess the expected operating range, not only one best-case measurement. A properly specified low-water-level protection arrangement may be required.
Finished inside diameter: Check casing clearance at the actual pump setting depth. Nominal well size alone is not sufficient.
Submergence: Keep the intake adequately below the lowest expected pumping level while allowing safe clearance from sediment. The final setting must follow the specific pump and motor installation instructions.
Water chemistry: Identify sand, suspended solids, salinity, pH and temperature. Material and abrasion resistance must be matched to the measured water conditions.
Power and controls: Confirm phase, voltage, frequency, cable run, protection arrangement and whether solar or grid supply is planned.
Do not confuse a pump's maximum immersion depth (a limit on how far below the water surface it may be installed) with its maximum hydraulic head (a performance characteristic). They are different specifications.
Once the well data and duty point are known, compare the relevant Stream ranges and obtain the exact model performance curve. These are product examples, not recommendations based on the illustrative 2 m³/h at 70 m duty point.
| Stream range | Published information | Buyer check |
|---|---|---|
| SP Series | 2–6 inch pump family; published maximum immersion 80 m; water temperature up to 35°C | Choose the precise diameter, stage count, Q-H curve and motor configuration |
| SCM / SSCM | Close-coupled, approximately 5 inch configuration; published minimum well diameter 127 mm and maximum immersion 80 m | Verify casing clearance and specific performance curve |
| Complete Deep Well Pump Range | Additional deep well pump designs and sizes | Compare water quality, installation space and electrical options |
SP Series conditions are those published on its current product page. Confirm whether the stated immersion, sand and temperature limits apply to the exact requested variant before ordering.
Send the following information to a supplier so different quotations can be compared on the same basis.
| Item | Information to Provide |
|---|---|
| 1. Required delivery | ___ m³/h or ___ L/min; daily volume ___ m³/day |
| 2. Well depth and diameter | Total depth ___ m; finished ID ___ mm |
| 3. Static water level | ___ m below reference level |
| 4. Pumping water level | ___ m at ___ m³/h; measurement date ___ |
| 5. Sustainable yield | ___ m³/h supported by pumping-test data |
| 6. Outlet conditions | Delivery elevation ___ m; required outlet pressure ___ bar |
| 7. Pipework | Pipe diameter, length, material, fittings and filters |
| 8. Water and power | Water analysis; voltage ___ V; ___ Hz; phase; controls |
Not necessarily. The required head depends mainly on the pumping water level, delivery conditions and hydraulic losses. Well depth affects where a pump can be installed, but it is not by itself the lifting head.
Use the expected pumping water level at the intended flow, allowing for seasonal variability where relevant. Static level alone may underestimate the required head.
No. First determine the flow and head required together, then verify that the chosen model can deliver that duty point on its published Q-H curve.
For a reliable deep well pump quotation, provide the measured pumping water level, sustainable yield, required flow and calculated total dynamic head. Add casing diameter, water quality and installation conditions. This prevents the common mistake of selecting a pump only by the depth printed on the well drilling report.
Explore the Stream deep well pump range or send your borehole data for a model quotation.
FAO — Groundwater Exploitation and Pump Selection: pumping-test yield, drawdown and equipment selection.
Stream — Deep Well Pump System Design: general system design background.
Stream — How to Choose a Deep Well Pump: pump construction and motor options.
The 90 m well and 70 m duty-point calculation are illustrative assumptions, not measured Stream product performance or a site-specific engineering design. Have installation and electrical work checked by qualified personnel.