Pump Knowledge

Deep Well Pump Selection: Water Level, Flow & Head

Nov. 20, 2026

How to Choose a Water Pump for a Deep Well: Water Level, Flow and Head

To choose a deep well pump, start with the pumping (dynamic) water level, sustainable well yield, required delivery flow and total dynamic head—not the depth of the well alone. Then confirm the borehole diameter, pump setting depth, water quality, electrical supply and the selected model's performance curve. The pump must deliver the required flow at the calculated head without exceeding the well's sustainable output.

1. Know the Four Different Well Depth Measurements

A 90 m well does not automatically require a pump rated for 90 m of head. These measurements describe different things:

MeasurementWhat It MeansWhy It Matters
Total well depthDistance from ground level to the bottomInstallation space and sediment clearance; not the required lifting head by itself
Static water level (SWL)Water level when the well is not being pumpedReference for calculating drawdown
Pumping / dynamic water level (PWL)Water level at the expected pumping ratePrimary water-level input to the pumping head calculation
Pump setting depthDepth at which the submerged pump is installedSubmergence, cooling, cable and installation clearance

Drawdown = pumping water-level depth − static water-level depth. It is the change in the water level during pumping, not an additional head term to add again to pumping water-level depth.

2. Calculate the Pump Duty Point, Not Just the Well Depth

For a simplified open-well supply system, use the expected pumping water level as the starting elevation and add the required delivery elevation, outlet pressure and friction losses. Use a consistent datum and avoid double-counting height or pressure.

Total Dynamic Head (TDH) ≈ pumping water-level depth below ground + discharge elevation above ground + required outlet pressure head + friction losses

Worked Example: 90 m Borehole, 40 m Pumping Water Level

Consider the following illustrative values, not measurements from a Stream installation:

Total well depth90 m
Static water level below ground24 m
Pumping water level below ground40 m
Pump setting depth below ground58 m
Delivery point above ground8 m
Required outlet pressure15 m of water
Estimated pipe and fitting losses at design flow7 m
Required pump duty point2 m³/h at 70 m head

The calculated head is 40 + 8 + 15 + 7 = 70 m, assuming a design flow of 2 m³/h. The pump is set at 58 m to remain submerged under the illustrative 40 m pumping water level; 58 m is not added again to TDH. Here the calculated drawdown is 16 m. In a real installation, the measured pumping water level and friction losses may change with flow and season.

The well's verified sustainable yield must also support the proposed 2 m³/h withdrawal rate. If it cannot, a higher-capacity pump will not solve the water-source limitation.

3. Match Pump Flow to Sustainable Well Yield

Request a borehole pumping-test record, including flow rate, stabilized pumping level (or measured level over the test), recovery data and any recommended abstraction limit. A pump with a higher maximum flow than the well can sustain may draw the level down excessively, increasing dry-running and sediment risks.

Where pumping levels fluctuate significantly, assess the expected operating range, not only one best-case measurement. A properly specified low-water-level protection arrangement may be required.

4. Confirm Borehole Diameter, Installation Depth and Water Quality

  • Finished inside diameter: Check casing clearance at the actual pump setting depth. Nominal well size alone is not sufficient.

  • Submergence: Keep the intake adequately below the lowest expected pumping level while allowing safe clearance from sediment. The final setting must follow the specific pump and motor installation instructions.

  • Water chemistry: Identify sand, suspended solids, salinity, pH and temperature. Material and abrasion resistance must be matched to the measured water conditions.

  • Power and controls: Confirm phase, voltage, frequency, cable run, protection arrangement and whether solar or grid supply is planned.

Do not confuse a pump's maximum immersion depth (a limit on how far below the water surface it may be installed) with its maximum hydraulic head (a performance characteristic). They are different specifications.

5. Stream Deep Well Pump Options to Review

Once the well data and duty point are known, compare the relevant Stream ranges and obtain the exact model performance curve. These are product examples, not recommendations based on the illustrative 2 m³/h at 70 m duty point.

Stream rangePublished informationBuyer check
SP Series2–6 inch pump family; published maximum immersion 80 m; water temperature up to 35°CChoose the precise diameter, stage count, Q-H curve and motor configuration
SCM / SSCMClose-coupled, approximately 5 inch configuration; published minimum well diameter 127 mm and maximum immersion 80 mVerify casing clearance and specific performance curve
Complete Deep Well Pump RangeAdditional deep well pump designs and sizesCompare water quality, installation space and electrical options

SP Series conditions are those published on its current product page. Confirm whether the stated immersion, sand and temperature limits apply to the exact requested variant before ordering.

6. Deep Well Pump RFQ Checklist

Send the following information to a supplier so different quotations can be compared on the same basis.

ItemInformation to Provide
1. Required delivery___ m³/h or ___ L/min; daily volume ___ m³/day
2. Well depth and diameterTotal depth ___ m; finished ID ___ mm
3. Static water level___ m below reference level
4. Pumping water level___ m at ___ m³/h; measurement date ___
5. Sustainable yield___ m³/h supported by pumping-test data
6. Outlet conditionsDelivery elevation ___ m; required outlet pressure ___ bar
7. PipeworkPipe diameter, length, material, fittings and filters
8. Water and powerWater analysis; voltage ___ V; ___ Hz; phase; controls

7. Common Questions

Does a 100 m deep well need a 100 m head pump?

Not necessarily. The required head depends mainly on the pumping water level, delivery conditions and hydraulic losses. Well depth affects where a pump can be installed, but it is not by itself the lifting head.

Should I use static or dynamic water level for pump sizing?

Use the expected pumping water level at the intended flow, allowing for seasonal variability where relevant. Static level alone may underestimate the required head.

Can I choose a pump by horsepower or maximum head?

No. First determine the flow and head required together, then verify that the chosen model can deliver that duty point on its published Q-H curve.

Conclusion

For a reliable deep well pump quotation, provide the measured pumping water level, sustainable yield, required flow and calculated total dynamic head. Add casing diameter, water quality and installation conditions. This prevents the common mistake of selecting a pump only by the depth printed on the well drilling report.

Explore the Stream deep well pump range or send your borehole data for a model quotation.

Technical basis and further reading

The 90 m well and 70 m duty-point calculation are illustrative assumptions, not measured Stream product performance or a site-specific engineering design. Have installation and electrical work checked by qualified personnel.